inbonaxx.blogg.se

Impulse rc driver fixer
Impulse rc driver fixer







impulse rc driver fixer

This issue occurs on both F4 & F7 FC's (both Aikon). You have to shut down the configurator, physically unplug & reconnect the USB & then load the configurator to regain functionality. After restarting the configurator even though the COM port is still visible in the drop-down menu, you CANNOT connect. Whenever the FC is instructed to reboot from within the configurator i.e.

impulse rc driver fixer

The configurator has to be loaded AFTER the USB connection has been plugged in to make the COM port available.

impulse rc driver fixer

If the configurator window is loaded BEFORE the USB connection is plugged in, the COM port does not appear in the drop-down menu. This has solved my issues with having to use the ImpulseRC driver fixer every time I connect a different FC, however the following issues still persist. I've performed a fresh install of Windows 8.1 & am currently using the latest nightly build of the configurator (10.8.0-debug-4d00fca6). I installed configurator version 10.7.1 & all of the above issues were NOT present.The ImpulseRC driver fixer has been ran on multiple occasions successfully.Configurator version: 10.9.0-debug-90f15faf.When typing save or bl into the CLI, the configurator should reboot & return me to either the previous tab that I was using, or in respect to the latter, the home page. When selecting save & reboot, the configurator should reboot & return to the previous tab that I was using. Expected behaviorĪfter successfully flashing the FC, the COM port should be displayed, which should then allow me to connect straight away & apply custom defaults. Restart configurator to return functionality.After restart, connect & apply custom defaults.No COM port available so restart configurator.Flash FC to any version (currently using 4.3 RC1).I have to restart the configurator in order to return functionality (the latter with the FC in DFU mode).In addition, when typing 'save' or 'bl' into the CLI, the FC reboots but the configurator hangs.I have to restart the configurator in order to return functionality.In addition when selecting save & reboot, the FC reboots but the configurator hangs.After connecting, the option to apply custom defaults is presented & the lights on the FC then display as normal.I have to restart the configurator in order for a COM port to be displayed.There is a constant single red light on the FC which could be misjudged as the FC being stuck in DFU mode, however I don't think that this is the case (I believe this is because the custom defaults have not been applied).After successfully flashing the FC via DFU, the FC reboots but the configurator does not display a COM port (only options are 'Manual Selection' & 'Virtual Mode').









Impulse rc driver fixer